MS500 Portable 5 in 1 gas detector
4,800.00 ₪
Flood detector SHV1 (level sensor)
Price on request
Level sensors (flood sensors) consist of metal sensing electrodes and a plastic head containing evaluation electronics. The connection of 24 VDC or 24 VAC supply voltage as well as the resting state of the relay or transistor output are indicated by a green LED. The failure state (forming of a conductive connection between the electrodes) is indicated by a red LED inside the box and a change of the state of the output transistor or relay contact. The selection of the relay output is done through the placement of a jumper on the PCB. All metal parts are made of stainless steel DIN 1.430, the basic length of the sensing electrodes is 50 mm. The supply cables are connected to the terminal board through bushings, which are part of the plastic head. The basic material of the head is POLYAMIDE. Level sensors (flood sensors) operates on the principle of different conductivity of air and water. Water becomes conductive to a certain extent due to dissolved mineral and organic substances. Under normal conditions (rain water), it has a conductivity of 5 mS/m and higher. This value reflects also on the setting of the sensitivity of the sensor with a margin (less than 1 mS/m). Once the electrodes are connected by a conductive medium, current starts to flow through the circuit (of the order of μA), which is then detected by evaluation electronics. This leads to state indication by a red LED, activation of the output transistor (open collector) or closing/opening of relay contacts. Level sensors (flood sensors) indicate fault conditions associated with water leakage in industrial plants as well as in rooms, offices or production halls within the range of 0 to 80 °C. The level sensors (flood sensors) meet the ingress protection of IP 65 according to EN 60 529, as amended and satisfy the conditions for operation in a normal, non-aggressive environment. The method of use must be chosen with regard to the temperature resistance of the sensor head and chemical resistance of the sensor housing and head. Possible applications: pump shutdown upon reaching a required level flooding of buildings by groundwater, floods, sewage flooding of sumps, pump activation upon reaching a certain level indication of water leakage from a washing machine, boiler, pump unit, etc. flooding of a room in the event of various equipment failures – broken toilet water supply line, overflowed bathtub, sink monitoring of condensate in a ventilation duct DECLARATION, CERTIFICATION, CALIBRATION Manufacturer provides EU Declaration of Conformity SPECIFICATIONS DIMENSIONAL DRAFT WIRING DIAGRAM DOWNLOAD Level sensor type SHV1 OUT R SHV1 OUT C Supply voltage 15 to 30 V DC/V AC for rele output; recommended 24 V DC/V AC 12 to 30 V DC/V AC for open collector output; recommended 24 V DC/V AC Temperature range around the head: 0 to 80°C sensing elektrode: max. 100 °C Output signal relay output output terminal of the open collector type Max. consumption without load approx. 15 mA Max. consumption with load approx. 35 mA Max. switching current 6 A Switching voltage up to 24 V DC/V AC Indication red LED – alarm state green LED – in operation, inactive alarm state Switching sensitivity alarm function active at fluid conductivity above 1 mS/m-1 Insulation resistance between electrodes ≥ 500 V DC (between electrodes not connected to the PCB) Ingress protection of the head IP65 acc. to EN 60529, as amended Head material POLYAMIDE Electrode amterial stainless steel DIN 1.4301 Dimensions head 90 x 63 x 34 mm including electrodes 141 x 63 x 34 mm Weight 125 g Note: Manufacturer reserves the right to make changes in design and technical characteristics of the products. For actual information, please always contact your dealer.
More in All Products
The whole category
MS500 Portable 5 in 1 gas detector
4,800.00 ₪
BH-60 Fixed Gas Detector to measure H2
Price on request
SC 102 - CO2 SENSORS TO THE INTERIOR WITH OUTPUT RS 485 (MODBUS)
Price on request
MIC500S O2 Fixed Gas Detector
3,120.00 ₪